Request a Representative

Your local representative can provide you with more information about HyperRHO S/D. Submit a request below. All fields required.

Request a Rep

All fields are required unless otherwise stated

Your details
Your request

* Check all that apply

HyperRHO® S/D (Rhₒ[D] immune globulin [human])
Ordering and reimbursement
Other
How would you like to be contacted?
Phone call
Email
Additional comments

0 characters left

I would like to receive future communications from Grifols (Optional)

Data Protection Information
The Grifols' group company to which you submit the request, as data controller, will process your personal data to manage your requests of information, suggestions and/or queries. The legal basis is Grifols' legitimate interest. Your data may be shared with Grifols' group companies and other third parties. You have the right to access, rectify and erase, as well as any other rights detailed in the additional information. For additional information on personal data protection check here.

By clicking the button below, I declare being informed that my data is being used as described in the data protection information.

Important Safety Information for HyperRHO® S/D Mini-Dose (Rhₒ[D] immune globulin [human])

HyperRHO® S/D Mini-Dose (RhO[D] immune globulin [human]) is recommended to prevent the isoimmunization of RhO(D) negative women at the time of spontaneous or induced abortion of up to 12 weeks' gestation provided the following criteria are met:

  1. The mother must be RhO(D) negative and must not already be sensitized to the RhO(D) antigen.
  2. The father is not known to be RhO(D) negative.
  3. Gestation is not more than 12 weeks at termination.

HyperRHO S/D Mini-Dose is made from human plasma. Products made from human plasma may contain infectious agents, such as viruses, and, theoretically, the Creutzfeldt-Jakob disease (CJD) agent that can cause disease. There is also the possibility that unknown infectious agents may be present in such products.

NEVER ADMINISTER HYPERRHO S/D MINI-DOSE INTRAVENOUSLY. INJECT ONLY INTRAMUSCULARLY. ADMINISTER ONLY TO WOMEN POSTABORTION OR POSTMISCARRIAGE OF UP TO 12 WEEKS' GESTATION. NEVER ADMINISTER TO THE NEONATE.

HyperRHO S/D Mini-Dose should be given with caution to patients with a history of prior systemic allergic reactions following the administration of human immune globulin preparations.

The attending physician who wishes to administer HyperRHO S/D Mini-Dose to persons with isolated immunoglobulin A (IgA) deficiency must weigh the benefits of immunization against the potential risks of hypersensitivity reactions. Such persons have increased potential for developing antibodies to IgA and could have anaphylactic reactions to subsequent administration of blood products that contain IgA.

As with all preparations administered by the intramuscular route, bleeding complications may be encountered in patients with thrombocytopenia or other bleeding disorders.

Although systemic reactions to immunoglobulin preparations are rare, epinephrine should be available for treatment of acute anaphylactic symptoms.

Other antibodies in the HyperRHO S/D Mini-Dose preparation may interfere with the response to live vaccines such as measles, mumps, polio or rubella. Therefore, immunization with live vaccines should not be given within 3 months after HyperRHO S/D Mini-Dose administration.

Animal reproduction studies have not been conducted with HyperRHO S/D Mini-Dose. It is also not known whether HyperRHO S/D Mini-Dose can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. HyperRHO S/D Mini-Dose is not indicated for use during pregnancy and it should be administered only postabortion or postmiscarriage.

Safety and effectiveness in the pediatric population have not been established.

Reactions to HyperRHO S/D Mini-Dose are infrequent in RhO(D) negative individuals and consist primarily of slight soreness at the site of injection and slight temperature elevation. While sensitization to repeated injections of human globulin is extremely rare, it has occurred.

Please see full Prescribing Information for HyperRHO S/D Mini-Dose.

You are encouraged to report negative side effects of prescription drugs to the FDA. Visit www.fda.gov/medwatch or call 1-800-FDA-1088.

Important Safety Information for HyperRHO® S/D Full Dose (Rhₒ[D] immune globulin [human])  

HyperRHO® S/D Full Dose (RhO[D] immune globulin [human]) is indicated for prevention of Rh hemolytic disease of the newborn (HDN) and the prevention of isoimmunization in RhO(D) negative individuals who have been transfused with RhO(D) positive red blood cells.

HyperRHO S/D Full Dose is made from human plasma. Because this product is made from human plasma, it may carry a risk of transmitting infectious agents, such as viruses, and, theoretically, the Creutzfeldt-Jakob disease (CJD) agent.

Never administer HyperRHO S/D Full Dose intravenously. Inject only intramuscularly. Never administer to the neonate.

RhO(D) immune globulin (human) should be given with caution to patients with a history of prior systemic allergic reactions following the administration of human immunoglobulin preparations. Such persons have increased potential for developing antibodies to IgA and could have anaphylactic reactions to subsequent administration of blood products that contain IgA.

As with all preparations administered by the intramuscular route, bleeding complications may be encountered in patients with thrombocytopenia or other bleeding disorders.

A large fetomaternal hemorrhage late in pregnancy or following delivery may cause a weak mixed field positive DU test result. If there is any doubt about the mother's Rh type, she should be given RhO(D) immune globulin (human). A screening test to detect fetal red blood cells may be helpful in such cases.

If more than 15 mL of D-positive red blood cells are present in the mother's circulation, more than a single dose of HyperRHO S/D Full Dose is required. Failure to recognize this may result in the administration of an inadequate dose.

Although systemic reactions to human immunoglobulin preparations are rare, epinephrine should be available for treatment of acute anaphylactic symptoms.

Administration of live virus vaccines (eg, MMR) should be deferred for approximately 3 months after RhO(D) immune globulin (human) administration.

HyperRHO S/D Full Dose should be given in pregnant women only if clearly needed because animal reproduction studies have not been conducted.

Reactions to RhO(D) immune globulin (human) are infrequent in RhO(D)-negative individuals and consist primarily of slight soreness at the site of injection and slight temperature elevation. While sensitization to repeated injections of human immunoglobulin is extremely rare, it has occurred.

Elevated bilirubin levels have been reported in some individuals receiving multiple doses of RhO(D) immune globulin (human) following mismatched transfusions. This is believed to be due to a relatively rapid rate of foreign red cell destruction.

Please see full Prescribing Information for HyperRHO S/D Full Dose.

You are encouraged to report negative side effects of prescription drugs to the FDA. Visit www.fda.gov/medwatch or call 1-800-FDA-1088.